Electrostatic Discharge (ESD) Practices
Appendix J
OEM6 Family Installation and Operation User Manual Rev 12
207
•
Do not allow chargeable plastics, such as binders, within 0.6 m of unshielded PCBs.
•
Do not allow a PCB to come within 0.3 m of a computer monitor.
J.3
Prime Static Accumulators
Table 55, Static-Accumulating Materials
on page 207 provides some background information on static
accumulating materials.
Table 55: Static-Accumulating Materials
J.4
Handling Printed Circuit Boards
ESD damage to unprotected sensitive devices may occur at any time. ESD events can occur far below the
threshold of human sensitivity. Follow this sequence when it becomes necessary to install or remove a circuit
board:
1. After you are connected to the grounded wrist strap, remove the circuit board from the frame and place it
on a static controlled surface (grounded floor or table mat).
2. Remove the replacement circuit board from the static-shielding bag or clamshell and insert it into the
equipment.
3. Place the original board into the shielding bag or clamshell and seal it with a label.
4. Do not put repair tags inside the shielding bag or clamshell.
5. Disconnect the wrist strap.
Work Surfaces
•
formica (waxed or highly resistive)
•
finished wood
•
synthetic mats
•
writing materials, note pads and so on
Floors
•
wax-finished
•
vinyl
Clothes
•
common cleanroom smocks
•
personal garments (all textiles)
•
non-conductive shoes
Chairs
•
finished wood
•
vinyl
•
fiberglass
Packing and handling
•
common polyethylene bags, wraps, envelopes and bubble pack
•
pack foam
•
common plastic trays and tote boxes
Assembly, cleaning and
repair areas
•
spray cleaners
•
common solder sucker
•
common soldering irons
•
common solvent brushes (synthetic bristles)
•
cleaning, drying and temperature chambers