background image

-

 13

 - 

NOVATEK-ELECTRO                                                                                                                                  EM-481

                                                                                                                                                             

 

Max. number of clients of 

MODBUS TCP 

Maximal  number  of  simultaneously  connected  clients  via  Modbus 
TCP - from the moment of start up 

136 

Max. load of 

MODBUS TCP, query/s 

Maximal  number  of  queries  received  per  second  from  the  clients  via 
Modbus TCP - from the moment of start up 

137 

Max. load of RS-485, % 

Maximal load of RS-485 for 5 minutes - from the moment of start up 

138 

Max. load of GSM, kB/s 

Maximal load of GPRS - from the moment of start up 

139 

Current IP-address of 

Ethernet 

IP-address, by which EM-481 device is accessible in Ethernet 
network* 

140 

– 143 

Current MAC-address of 

Ethernet 

MAC-address, by which EM-481 is detected in Ethernet network 

144 

– 149 

Unused parameter 

The parameter is reserved for compatibility and is equal to 0 

150 

– 164 

 

Time to connect to the 

data collection server  

 

0 - connection to the data collection server is set; 
1 - connection to the data collection server is performed; 
2 - 65534: the number of seconds before reconnecting; 
65535: connection to the server is not used. 

165 

Number of programmed 

restarts 

Number of restarts in accordance to the user setting - for total 
operational time 

166 

Number of critical errors 

Number of noted errors (failures) causing the restart of the device - for 
total operational time 

167 

Total operation time, min  The number of minutes of operating time - for the total operational 

time 

168 

– 169 

Current time 

Number of seconds since 1st of January of specified year (see reg. 172) 

170 

– 171 

Year of countdown 

Year, since 1

st

 of January which is taken for time counting 

172 

Time zone, min  

Time  zone,  for  the  time  count,  number  of  minutes  with  sign  as  to 
UTC+00 

173 

Temperature

, °C 

Temperature inside EM-481 

174 

Power voltage, mV  

Bus voltage of 12 V 

175 

 

Time before connection to 

remote server Modbus 

TCP 

0 - connection to the remote server is set; 
1 - connecting to the remote server; 
2 - 65534: the number of seconds before reconnecting; 
65535: Connection to the Modbus TCP server is not used. 

176 

Interface of connection to 

remote server of Modbus 

TCP 

0 - the connection is not set; 
1 - Ethernet connection is set; 
2 - GPRS connection is set. 

177 

DST increment, min 

Effective day saving time increment 

178 

Unused parameter 

The parameter is reserved for compatibility and is equal to 0 

179 

IP-address of client 1** 

IP-address of client, 0.0.0.0 

– not connected 

180 

– 183 

Port of client 1** 

Port of client, 0 

– not connected 

184 

IP-address of client 2** 

IP-address of client, 0.0.0.0 

– not connected 

185 

– 188 

Port of client 2** 

Port of client, 0 

– not connected 

189 

IP-address of client 3** 

IP-address of client, 0.0.0.0 

– not connected 

190 

– 193 

Port of client 3** 

Port of client, 0 

– not connected 

194 

IP-address of client 4** 

IP-address of client, 0.0.0.0 

– not connected 

195 

– 198 

Port of client 4** 

Port of client, 0 

– not connected 

199 

Unused parameter 

The parameter is reserved for compatibility and is equal to 0 

200 

– 209 

Year (current time) 

Current year 

210 

Month (current time) 

Current month 

211 

Day of the month (current 

time) 

Current day of the month 

212 

Hour (current time) 

Current hour 

213 

Minute (current time) 

Current minute 

214 

Second (current time) 

Current second 

215 

Day of week (current time)  Current day of week (1 - Monday) 

216 

Month (winter time) 

Current month, excluding summer time 

217 

Day of the month (winter 

time) 

Current day of the month, excluding summer time 

218 

Hour (winter time) 

Current hour, excluding summer time 

219 

Unused parameter 

The parameter is reserved for compatibility and is equal to 0 

220 

– 229 

Time of day, s 

Number of seconds from midnight of the current day 

230 

– 231 

Time of sunrise, s 

0

–86399: Number of seconds from midnight to sunrise; 

86400: Sunrise is not observed on this day 

232 

– 233 

Table 5.7 Continued 

Parameter 

Description 

Address 

Summary of Contents for EM-481

Page 1: ...development and production complies with the requirements of ISO 9001 2015 Dear Customer NOVATEK ELECTRO Ltd Company thanks you for purchasing our products You will be able to use properly the device...

Page 2: ...d via RS 485 9 5 2 2 3 Access to MODBUS network using MODBUS TCP 9 5 2 2 4 Access to MODBUS network using SMS 9 5 2 2 5 Data collection and event tracking 10 5 3 Configuration 10 5 3 1 General 10 5 3...

Page 3: ...THE HOUSING IT IS NOT ALLOWED WATER PENETRATION ON TERMINALS AND INTERNAL ELEMENTS OF THE DEVICE During operation and maintenance the regulatory document requirements must be met namely Regulations fo...

Page 4: ...ing and transferring data IP protocol is routable protocol for transferring data by Ethernet It is a part of TCP IP and used for Internet IP address is a node address which is unique within a single n...

Page 5: ...showing of warnings about detected faults 4 GSM LED is blinking every 3 sec when there is connection via GSM network or UMTS it is blinking 3 times per second while data exchanging via GPRS or HSPA 5...

Page 6: ...ort circuit output voltage of driver RS 485 maximum mA 250 Resistance of in built terminator Ohm 1000 The recommended number of connected devices in Modbus network when the input current of receivers...

Page 7: ...vice operation Check the device for damage after transportation in case of such damages detection contact the supplier or the manufacturer Carefully study the Operating Manual pay special attention to...

Page 8: ...in the SIM slot and connect the GSM antenna to the ANT connector SMA F connector 5 2 Using the device 5 2 1 General After power is turned on all indicators except LAN and GSM light up and EM 481 perf...

Page 9: ...addresses identifiers If the query could not be redirected for example in the RS 485 slave mode if the connection to the remote MODBUS TCP server was terminated the EM 481 can generate and send the MO...

Page 10: ...ters of address in Ethernet network if Ethernet is used and server address to which EM 481 is connected automatically The adjustable parameters are described in items 5 3 2 The parameters remain saved...

Page 11: ...ess MAC 48 from left to right 6 Table 5 5 Parameters describing the device Parameter Description Address Device type The code that defines the MODBUS product by the manufacturer 23 EM 481 0 Firmware v...

Page 12: ...d access tabs 0 no permission 1 there is permission Bit 6 It is always as 1 Bit 7 Permission for the connected client to configure EM 481 the same as register 121 0 no permission 1 there is permission...

Page 13: ...on to remote server Modbus TCP 0 connection to the remote server is set 1 connecting to the remote server 2 65534 the number of seconds before reconnecting 65535 Connection to the Modbus TCP server is...

Page 14: ...parameters Parameter Range of values Factory setting Description Address Ethernet network Static IP address IP address 192 168 0 111 If the dynamic addressing is switched off or not available IP addre...

Page 15: ...vice provider up to 24 characters 392 415 APN address of host Character string Provided by the GSM service provider up to 34 characters there cannot be spaces in a string 416 449 MODBUS TCP clients Co...

Page 16: ...tart bit 7 data bits 2 stop bits or parity bit and stop bit total is 10 bits The non standard byte formats register 461 values 4 and 5 are not available in this case format 3 2 stop bits is used inste...

Page 17: ...ssword This string should not have any spaces 540 549 The specified password for recording per mission via MODBUS TCP in devices using RS 485 Character string It is used to access devices connected to...

Page 18: ...Gateway Path Unavailable response is not returned to the client 1 255 if there is no connection to the query addressee this exception code is returned to the client 636 Enable RS 485 slave mode 0 1 0...

Page 19: ...aylight saving time 1 10 10 It is used if you selected the automatic transition to daylight saving time on the specified days Week of the month when the clock will be set one hour ahead 1 5 week of th...

Page 20: ...f clock for synchroniza tion s 1 180 2 It is used if you have enabled synchronization of clocks with the server clock The synchronization is performed after receiving the server time if the difference...

Page 21: ...ears once again 5 3 4 EM 481 configuring via MODBUS interface Setting via Modbus interface shall be provided if the device is connected using the Modbus client which is supporting the Modbus TCP proto...

Page 22: ...return and transfer it to the warranty post warranty service please indicate detailed reason for the return in the field of the claims data 8 TRANSPORTATION AND STORAGE The device in the original pack...

Page 23: ...in the GSM network is displayed alternately with the IP address in the local Ethernet network The operation speed with remote Modbus TCP server is improved The speed of GSM operation is increased 30...

Page 24: ...481 Parameter Value Addressing using DHCP Yes IP address 192 168 0 111 Subnet mask 255 255 255 0 Gateway 192 168 0 1 With the factory settings of the EM 481 two ways are possible for communicating wi...

Page 25: ...ter closing the windows answer yes 3 Connection to Internet via Ethernet ATTENTION THE USER IS STRONGLY RECOMMENDED TO CONNECT THE UNIT TO INTERNET UNDER THE SUPERVISION OF THE LAN SYSTEM ADMINISTRATO...

Page 26: ...om the client over the long period the access returns to locked mode ATTENTION DURING ANY CONNECTIONS EXCEPT FOR TRANSMITTING VIA GSM AND COMMUNICATION WITH SERVER VIA SPECIAL PROTOCOL EM 481 THE PASS...

Page 27: ...age in order to delete the device from Overvis system That guarantees that the EM 481 device will be used only by the authorized users Using the instruction on the site of Overvis system connect to EM...

Page 28: ...again the internal memory to re read the program Files can have arbitrary names and extensions and placed in subfolders of the folder TASKS Files placed directly in the folder TASKS allow you to use...

Page 29: ...s The file can contain comment lines that begin with and are ignored when reading the file Correct example Incorrect example This is a comment VARS number of seconds per minute 0 VAL 60 1 VAL 1 This i...

Page 30: ...eters in the task file which are accessed through RS 485 and GSM interfaces By default if no modifier is specified it is 0 PARAMACTUAL ushort Frequency of reading the parameters in seconds It allows o...

Page 31: ...in a single query WRHMULTIPLE uchar uchar Device can write only using function 16 in the storage registers The first argument specifies how many registers can be read in one query the second one deter...

Page 32: ...point 100 F32BLEEP3R 32 bit with reverse order of bytes and floating point 1000 F32WLEEP0R 32 bit with reverse order of words and floating point F32WLEEP1R 32 bit with reverse order of words and floa...

Page 33: ...all variables in the specified range VARSMINIDX var ref var ref The number of the minimum variable in the specified range VARSMAX var ref var ref Maximum of all variables in the specified range VARSMA...

Page 34: ...ref Copy of the condition CONDIS int Set to the specified value The condition is met if the value is not 0 It can be used for adjustment or for unconditional actions for each update cycle NOT cond ref...

Page 35: ...has the following format index action type argument 1 argument 2 Index the sequential number of the line The types of the arguments int 32 bit signed integer alarm reason is the number of reason of t...

Page 36: ...n the text 3 MODBUS ID of the device is OM 310 240 is the register address which is monitored for the fault enabling relay 1 depending on bit 0 of register 240 of device 3 META 8th version of Protocol...

Page 37: ...hieving the temperature respectively the lower or upper limits These registers are read only To change them you should be in configuration mode see it 5 3 4 then write the desired values to addresses...

Page 38: ...VARGEVAR V2 V1 in other cases do not change the hysteresis current value 2 CONDIS 1 VARS the desired hysteresis is selected from V3 V5 according to the conditions of C0 C2 6 VARSSELBYC V3 C0 CONDS is...

Page 39: ...ting select the file of updating The procedure for file selection is given in Table D 2 To cancel the updating cut off the power supply of EM 481 or wait until automatic completion of updating mode Ta...

Page 40: ...Similar to No 2 but the file with an error has less priority The error is automatically corrected with available files of updating 4 The files of updating are not available Escape from the mode of upd...