PRECESSION ELEPHANT 2 Scan Head 2
No. Label / description
Action
⑤
DC INPUT
–
OR
–
SERVICE connector
If this connector is named DC
INPUT then connect it with a
power cable to one of the
SCAN HEAD POWER connectors
of the ASC system controller,
see
ff.
If this connector is named
SERVICE then do not connect it.
NOTICE
Voltage peaks and leakage currents, when hot plugging the power supply,
destroy the scan head electronics.
•
Before connecting the power supply to the scan head or disconnecting it
from the scan head, ensure that no voltage is being applied to the
connecting cable.
⑥
DC INPUT
This connector is not present at some variants of
the scan head; see also no. 5
If applicable then connect this
connector with a power cable
to one of the SCAN HEAD
POWER connectors of the ASC
system controller, see
on page
ff.
NOTICE
Voltage peaks and leakage currents, when hot plugging the power supply,
destroy the scan head electronics.
•
Before connecting the power supply to the scan head or disconnecting it
from the scan head, ensure that no voltage is being applied to the
connecting cable.