PRECESSION ELEPHANT 2 Scan Head 2
14.
CAUTION
Visible or invisible laser radiation
could cause damage to eye or skin.
•
Avoid eye or skin exposure to direct or scattered radiation.
Click
Start Testmark
.
15. Wait until the marking is done and then remove the workpiece.
16. If the marking is OK then click
Next
–
OR
–
If the marking is
not
OK then repeat
the test mark.
17. On the workpiece, select the largest square that is completely marked. As a
general rule this is square II. The squares are numbered by marking lines
beginning at the most inner square outwards like this:
18. On screen in
Step 6
, type the number of this square in
Measure Square
.
19.
Pay attention to the work piece’s orientation and measure the distances
requested on screen in
Step 6.
Type them in the respective fields.
20. As
Correction algorithm
select
Parabola average
.
21. Click
Start calculation
.
22. Click
Next
.
23. In
Step 7
, check the correction of the scan field by a testmark if necessary.
The procedure is the same as before.
24. Click
Next
.
25. In the
Final Step
, click
Save to controller
.
26. Optionally click
Save to file
.
The correction is saved now.
55