PRECESSION ELEPHANT 2 Scan Head 2
No. Label / description
Action
⑦
SYNC
connector for the laser’s trigger
signal
output
This connector is optional.
If you wish to measure the
energy of single laser pulses
then connect it with a BNC-
cable to trigger signal output
of laser.
Find more information in
[
] in section
Devices:Sensor
AfemLight
.
⑧
BEAM SWITCH connector for control of an
external beam switch
This connector is optional.
If a beam (path) switch is
present in your system then
connect with a CAT-5 patch
cable to the beam switch.
⑨
USB 1 USB 2 USB 3 connectors for the built-
in through-the-lens vision camera and
2 alignment cameras
If USB cameras are built-in then
connect this to a PC.
See also [
⑩
Beam entry
None
⑪
Objective
None
⑫
Optionally adjustable gas nozzle and optional
suction cup
None
⑬
ETHERNET connector for connecting the built-
in through-the-lens vision camera and
2 alignment cameras
If Ethernet cameras are built-in
then connect this to a PC.
See also [
⑭
NOZZLE
Process gas inlet;
Process gas quality: non-corrosive gases used
commonly as process gases;
Inlet pressure: depending on nozzle up to 4 bar
(400 kPa);
Recommend tubing material:
polyetherurethane; D 6 mm, d 4 mm
Connect with tube to process
gas supply; see also section
23