INVENTORY
PAGE
|
18
i401 contents description
Each item below is also listed in tables that follow:
i401 400 W Laser
–
i401 laser is a compact, single tube 400 W laser producing near-perfect beam
quality with < 100
µ
s rise/fall times and a PWM duty cycle range from 1% up to 100% (full CW operation).
Customer Communication Flier
–
contains a i401 website location information that provides setup,
operation, and maintenance information for your i401 laser.
Ethernet Crossover Cable
–
provides the communications link between a host and the laser for
accessing operating parameters via a TCP/IP web-based interface.
BNC Control Cable
–
Coaxial cable carries the PWM Command signal from the UC-2000 Controller to
the laser
’
s Quick Start Plug.
12 mm Cooling Tubing
–
carries cooling water from the chiller to the laser and back. This clear
polyethylene tubing is 12 mm O.D. by 30 feet and must be cut to length.
DC Power Cables
–
carry DC power from the 48 V power supply to your i401 laser. Standard cable
length is 2.0 meters (6.5 feet) while optional 5.0 m (16 ft) power cables are available.
Quick Start Plug
–
connects to 401’s User I/O connector. Jumpers are built into the plug to enable Fire-
star
’
s interlock circuits for initial start-up and testing.
1/2" Tubing Fitting Kit
–
provides a means to replace the i401
’
s 12 mm fittings with fittings that accept
1/2" coolant tubing. See the Connecting section for installation details.
Mounting Hardware Kit
–
fasten i401 to your mounting surface. Four each M10
×
1.5
×
35 mm cap
screws and M10 washers are provided for mounting the i401 laser.
Gas Purge Kit
–
provides a filtering and connection point to the laser from your facility
’
s purge gas
system.
Spare Fuses (not shown)
–
40 ampere fast-blow fuses protect i401’s internal RF circuitry.
Final Test Report (not shown) – Contains data collected during the laser’s final pre-shipment test.