4. Preparing for use
4.3. Installing
Table 4.14.: Pin assignment of the
IOIOI
interface when used as RS-232/CAN
interface
Pin
Name
Description
1
CANL
Differential CAN low signal, 3.3 V level
2
RxD
Receive data signal, 3.3 V level
3
TxD
Transmit data signal, 3.3 V level
4
GND_ISO
Isolated ground
5
GND_ISO
Isolated ground
6
CANH
Differential CAN high signal, 3.3 V level
7
RTS
Ready for receiving, 3.3 V level
8
CTS
Clear to send, 3.3 V level
9
n. c.
Reserved
S
Shield
Shield
– OR –
Table 4.15.: Pin assignment of the
IOIOI
interface when used as RS-485/CAN
interface
Pin
Name
Description
1
CANL
Differential CAN low signal, 3.3 V level
2
Ra
Receive data signal, 3.3 V level
3
Dy
Transmit data signal, 3.3 V level
4
GND_ISO
Isolated ground
5
GND_ISO
Isolated ground
6
CANH
Differential CAN high signal, 3.3 V level
7
Dz
Inverted transmit data signal, 3.3 V level
8
Rb
Inverted receive data signal, 3.3 V level
9
n. c.
Reserved
S
Shield
Shield