4. Preparing for use
4.3. Installing
PROCEDURE
NOTICE
Voltage peaks and leakage currents, when hot plugging the power
supply,
destroy the scan head electronics.
• Before connecting the power supply to the scan head or dis-
connecting it from the scan head, ensure that no voltage is
being applied to the connecting cable.
• Connect the scan head power supply according to the following specifi-
cation to the scan head.
SPECIFICATION OF THE SCAN HEAD POWER SUPPLY
• Labeled:
POWER A,
POWER B
• Cable length typical 5 m
A1
A2
A3
Connector type of the scan head power supply: (D-Sub) DA-F-M-M-A_3W3
Table 4.5.: ASC-6 V41: Pin assignment of the scan head power supply
Pin
Name
Description
A1
PWR
+48 V; 10 A
A2
n. c.
Do not connect
A3
GND
Ground
S
GGND
Frame ground
ASC_ARGNET-series_manual, 2022-02-15