4. Preparing for use
4.3. Installing
4.3.5. CONNECTING THE POWER SUPPLY TO THE SCAN HEAD
4.3.5.1. MODELS ASC-1, ASC-2 V41
TARGET AUDIENCE AND QUALIFICATION
Experts
PROCEDURE
NOTICE
Voltage peaks and leakage currents, when hot plugging the power
supply,
destroy the scan head electronics.
• Before connecting the power supply to the scan head or dis-
connecting it from the scan head, ensure that no voltage is
being applied to the connecting cable.
• Connect the scan head power supply according to the following specifi-
cation to the scan head.
SPECIFICATION OF THE SCAN HEAD POWER SUPPLY
• Labeled:
POWER A,
POWER B
• Cable length typical 5 m
A1
1 2 A2
3 4 5
Connector type of the scan head power supply: (D-Sub) DA-7W2P
ASC_ARGNET-series_manual, 2022-02-15