4. Preparing for use
4.3. Installing
1
6
7
12
Connector type of the “safety” connector: 12 pin socket HARTING HAN DD
module 09 14 012 3101 with housing 09 14 001 0301
Table 4.10.: ASC-6 V41: Pin assignment of the “safety” connector
Pin
Name
Description
1
EM_EXT_LED
Output signal “SFT (safety) board ready”;
24 V; max. 20 mA
Connect an emergency stop switch with:
2
EM_NCC_2
Normally closed contact; pin 2
3
EM_NCC_1
Normally closed contact; pin 1
4
EM_NOC_2
Normally opened contact; pin 2
5
EM_NOC_1
Normally opened contact; pin 1
6
GND
Ground
7
PWR_OUT
Output; 24 V; max. 2 A
Connect an interlock with:
8
IL_NCC_2
Normally closed contact; pin 2
9
IL_NCC_1
Normally closed contact; pin 1
10
LASER_ON_LED
Output signal “laser on”; 5 V; max. 50 mA
11
REM_START_N
Input signal “remote start”; brings the SFT
(safety) board back to ready state after a
non-auto-recoverable event; 24 V; max. 10 mA;
switches at 3 mA raising edge; negative pin
ASC_ARGNET-series_manual, 2022-02-15