21.7.2 Other repairs
Any other repairs of the load-bearing structures (e.g. cylinders) must also be entered in
the inspection record under "Remarks”, including the following information:
-
Location of repair
-
Date
-
Repairer
-
Make sure that the manufacturer’s instructions have been observed.
21.7.3 Test loading (= overloading)
After repairs of load-bearing structures or cylinders, the Access Platform must be tested
while being loaded according to standard EN280. The test load used must be entered in
the inspection record.
With machine-driven lifters, the test load must be 125% of the nominal load, i.e. 288 kg for
Nostolift XS 240. The test is carried out by releasing the adjustment screws of load control
completely for the duration of test loading. After test loading, load control must re-
adjusted.
All movements with the test load must be carried out using acceleration and deceleration
required by safe load management. When several different types of movements (such as
lifting, lowering, slewing, transfer) must be carried out with the test load, they must be
carried out once the swinging caused by the preceding movements has stopped,
individually, and by paying attention to the most unfavourable positions.
If, because of the many different load and side reach combinations of the MEWP, test
loads of varying weights are needed, all movements must be tested with all test loads
unless the most unfavourable conditions can be simulated sufficiently well through a single
performance test.
In the overload test, the MEWP must be located on an even base, and the lifting
mechanism must be placed in each such position which causes the maximum strain on
each load-bearing structure of the MEWP.
This test does not need to simulate the impact of the maximum permitted wind.
In the overload test, the brake systems need to be able to stop the test load(s) and keep
them stopped. After removing the load(s), there must be no permanent deformations on
the MEWP.