XS
240
SELF-PROPELLED TELESCOPIC PLATFORM
- In extremely cold weather, let the combustion engine run for a few minutes and then
warm up the hydraulics by performing some movements with the booms at slow speed.
- Protect the platform and controls from snow and ice when not working with the Access
Platform.
12.2
THINGS TO REMEMBER WHEN WORKING ON THE
PLATFORM OR WHEN MOVING FROM SITE TO SITE
- Observe the minimum safe distances to live electrical conductors.
- Do not damage the work platform or the controls.
- Do not throw down objects from the platform and make sure that nothing can fall down.
- Do not reach out of the platform.
- Do not use ladders or any other reaching devices in the platform.
- Do not swing or jump in the platform.
- Make sure that the platform is always in horizontal position.
WARNING! IF THE OUTREACH EXCEEDS THE VALUES GIVEN IN BOOM
GEOMETRY, REPAIR THE ACCESS PLATFORM OR HAVE IT REPAIRED BEFORE
NEXT USE. DO NOT USE A FAULTY ACCESS PLATFORM. THE MAXIMUM ALLOWED
PLATFORM LOAD IS 230 KG.
12.3
USE OF SUPPLY CURRENT ON THE PLATFORM
Connect the supply current 220V/50Hz 16A to the outlet beside the equipment case on the
chassis. The platform has two earthed outlets for hand tools. The electric line is fitted with
a ground fault circuit interrupter and a slip-ring package inside the pivot bearing. The
ground fault circuit interrupter is in the equipment case, and it has a test button for
checking the line before use. The ground fault circuit interrupter is also fitted with a supply
voltage breaker.
12.4
TESTING THE GROUND FAULT CIRCUIT INTERRUPTER
- Plug in a device, for instance a drilling machine, in the outlet on the platform. Engage
supply current to the Access Platform (220 - 240V/50Hz) with an earthed cable. Press the
test button of the ground fault circuit interrupter thus releasing the main power switch,
which serves as an automatic fuse. Should the main power switch not be released and if
the device has not functioned on the platform before this, you have to check that the main
power switch is in its power supplying position.
- Should the switch be released in normal use, either the electric line or the tool is faulty.
Stop the use of the tool immediately and have the equipment repaired.