XS
240
SELF-PROPELLED TELESCOPIC PLATFORM
7. Open the oil cap (1) and fill the crankcase with new oil. Check that the oil level is up to
the upper mark of the dipstick (4).
8. Close the oil cap and replace the dipstick. Let the motor run for a few minutes. Check
for oil leaks and after oil pressure is stable check the oil level with the dipstick. Add more
oil, if needed.
9. Reinstall the hood of the service opening.
19.6
LUBRICATION SCHEME
Figure 23. Lubrication scheme
Lubricate the following points every fifty (50) operating hours:
1.
Articulation bearings for platform slewing
2.
Bearing surfaces, joints and diaphragm springs of lifting radius guard and
contact surfaces of adjustment pin
3.
Outrigger joints and articulation bearings of cylinders
4.
Joints of supporting plates
5.
Articulation bearings of boom and turntable
6.
Articulation bearings of platform stabilizer arms
7.
Articulation bearings of lifting cylinder
8.
Articulation bearings of jib cylinder
9.
Sliding surfaces of boom and chain sprocket bearings