®
XS
240
SELF-PROPELLED TELESCOPIC PLATFORM
9. Remove some of the load from the platform. The overload alarm should go off and the
‘Max. platform load’ text should disappear. Note measuring accuracy.
10 If the platform load control does not operate properly, grease the bearings (3) of the
cranks (2), 8 in all, and repeat the check. If needed, adjust according to the following
instructions.
Adjustment
1.
Remove the display cover
2.
Switch on the current with the platform ignition lock
3.
Acknowledge the text on the display by pressing F1 OK
4.
Press ESC to enter the menus
5.
Move up/down the menus using the arrow keys
6.
Look for the menu settings
7.
Select
F3 OTHER
32
F1
F2
F3
ESC
Nuoli
ylös
Nuoli alas
Summary of Contents for XS240
Page 1: ...XS240 SELF PROPELLED TELESCOPIC PLATFORM OPERATION MAINTENANCE...
Page 6: ...XS 240 SELF PROPELLED TELESCOPIC PLATFORM 4 SPECIFICATION Figure 3 Specification 5...
Page 10: ...XS 240 SELF PROPELLED TELESCOPIC PLATFORM 5 1 NOSTOLIFT XS 240 BOOM GEOMETRY 9...