Figure 5-7.
Door 2 with Free Egress.
Valid code use at Card Reader (or Keypad) 2 OR
egress attempt (at Input 6) triggers the pulse time of Output Relay 2, unlocking Door 2 for 10
seconds. The activation of Output 2 triggers the shunt time of Input 2 (via the interlock),
shunting Door 2 status switch for 15 seconds. Input 2 is shunted for the duration of its shunt
time (15 seconds by default) upon valid code use OR upon egress attempt. Door 2 shunt time is
determined by Input 2 shunt time, NOT Input 6 shunt time. Input 6 shunt time does not apply.
WARNING!
Panel must be
earth grounded.
Panel must be
earth grounded.
WARNING!
S-4 SUPPRESSION
REQUIRED ACROSS
EVERY ACTIVE RELAY
AND ELECTRICAL
DEVICE (CONNECT
WITHIN 18 INCHES).
S-4 SUPPRESSION
REQUIRED ACROSS
EVERY ACTIVE RELAY
AND ELECTRICAL
DEVICE (CONNECT
WITHIN 18 INCHES).
Lock Solenoid
1
3
4
5
6
7
8
9
10
2
11
12
Lock Power Supply
Lock Power Supply
K3
K4
K 1K 1
K5
K10
K6
K7
K8
K2
Card Reader 2
Card Reader 1
Card Reader 1
Common
N-1000-III
Door Status Switch
(Input Point 2)
Shunt Time =
15 seconds
Egress (exit) device
(Input Point 6)
Shunt Time = 0
Input point 6
Output point
(relay ) 2
pulse time =
10 seconds
Door 2
Input 2