A–6
N-1000-III/IV
N-1000-III/IV
N-1000-III/IV
N-1000-III/IV
N-1000-III/IV
Appendix A: Quick Reference Guide
Sub-
Sub-
Sub-
Sub-
Sub-Command 2
Command 2
Command 2
Command 2
Command 2
Function:
Set the device from which a PIN is expected for a given card reader.
Eliminates required PIN use at specified card reader.
Syntax:
_A
=pn_dev
_D_Ø_
dev<CR> (first dev = card reader,
second dev = keypad)
Example:
_
A
=1_2_
D
_Ø
A PIN is not required for access at Card Reader 2 (Device 2) on Panel 1.
(This is the most common use of this command.)
C Command
C Command
C Command
C Command
C Command
Sub-
Sub-
Sub-
Sub-
Sub-Command 1
Command 1
Command 1
Command 1
Command 1
Function:
Add a single or multiple codes to memory with special options.
Syntax:
_C
=pn_code_tz_dev [_i/o][_A][_K][_L_#][_P_#][_T][_N_desc]<CR>
User
options:
A:
Set Anti-passback feature to “IN” (card added with “IN” status.)
(NOTE: the default status of cards is “Unused”)
K:
No PIN required
L_#: Limited code use
P:
Personal Identification Number (PIN)
T:
Trace code
N:
Name (must not be used with access control software)
Example:
_
C
=1_594_1_1_2_
A_P_
12345
Card number 594 is valid with PIN 12345 during Time Zone 1 at both
card reader/keypad 1 and card reader/keypad 2 (devices 1 and 2) on
panel 1.
Sub-
Sub-
Sub-
Sub-
Sub-Command 2
Command 2
Command 2
Command 2
Command 2
Function:
Allow cards to have different time zones per reader or keypad on a
single panel. Panel must be initialized with I Command, Z_Ø option.
Syntax:
N-1000-II
_C
=pn_card#_tz1_tz2_{dev1/dev3}_{dev2/dev4}<CR>
or
N-1000-III/IV
_C
=pn_card#_tz1_tz2_tz3_tz4_{dev1/dev5}_{dev2/dev6}_{dev3}_{dev4}<CR>
Example:
_
C
=1_750_1_3_1_2
Card number 750 is valid at panel during Time Zone 1 on Reader 1 and
Time Zone 3 on Reader 2.