Appendix A: Quick Reference Guide
N-1000-III/IV
N-1000-III/IV
N-1000-III/IV
N-1000-III/IV
N-1000-III/IV
A–1
Appendix A: Programming Quick Reference Guide
Preface
Preface
Preface
Preface
Preface
The following Programming Guide applies to the N-1000-II and the N-1000-III/IV
panels. The text indicates where there are differences between the N-1000-II
and the N-1000-III/IV. These panels can be programmed using Northern’s
access control software installed on a PC. Information on time zones, areas, panel
variables and access levels can be managed automatically using this software.
These operations can also be performed via terminal or printer/programmer. This
Programming Guide provides basic code format information necessary to program
the N-1000-II and N-1000-III/IV control panels. For complete
explanations and examples, contact the factory.
Note:
If the N-1000-II or the N-1000-III/IV is to be used in an existing
N-1000-II system, the N-1000-II must be at least version 7.0 panel firmware.
Notation Conventions
Notation Conventions
Notation Conventions
Notation Conventions
Notation Conventions
The following notation conventions are used:
bold
Literal elements of a command that must be entered exactly as
shown.
italic
Variables that must be defined by the user. Descriptions of these
variables follow this section
_
(underscore)
A space
<
CR
>
The ENTER key (Carriage Return)
[ ]
Brackets surround optional command elements.
{ }
Braces surround two or more choices
|
A vertical bar separates individual choices within the braces:
{choice 1 | choice 2 | choice 3}. The user must select only one
of the choices.
Invalid Code Error Messages
Invalid Code Error Messages
Invalid Code Error Messages
Invalid Code Error Messages
Invalid Code Error Messages
Error Message
Violation
AP
Anti-passback violation.
EX
Code expired (Limited Use or Visitor status)
NF
Code not found (programmed) in memory for the
selected card reader or keypad.
TR
Trace message (enabled with the C Sub-command 1/T
option).
Access is allowed.