BES50 advanced features configuration
Variable definitions
Variable
Value
Port
The port number.
Ingress
Select to enable policy settings and select a policy map.
Configuring address tables
Switches store the addresses for all known devices. This information passes
traffic directly between the inbound and outbound ports. The dynamic
address table stores all addresses learned by monitoring traffic. You can
also manually configure static addresses bound to a specific port.
Navigation
•
"Changing the aging time" (page 84)
•
"Setting static addresses" (page 85)
Changing the aging time
You can change the aging time for entries in the dynamic address table.
Procedure steps
Step
Action
1
From the main menu, choose Applications > Address Table >
Address Aging.
2
Specify the new aging time.
3
Click Submit.
—End—
Variable definitions
Variable
Value
Aging Status
Select to enable the aging time.
Aging Time
Type the time after which a learned entry is discarded. (Range:
BES50FE-12/24T 10 to 630 seconds; BES50GE-12/24T 10 to
1 000 000 seconds; Default: 300 seconds)