Configuring port mirroring
61
Procedure steps
Step
Action
1
From the main menu, choose Configuration > Port > Port
Broadcast Control or choose Configuration > Port > Trunk
Broadcast Control.
ATTENTION
BES50GE-12/24T does not support trunk broadcast control.
2
Select the Enabled check box and type a threshold for each port
and trunk.
3
Click Submit.
—End—
Variable definitions
Variable
Value
Port
Indicates the port number.
Protect Status
Select to enable broadcast storm control. (Default: Enabled)
Threshold
Enter threshold as acpercentage of port or trunk bandwidth.
For BES50GE-12/24T, the threshold setting is a global setting for
all ports. (Default: 64 packets per second)
Trunk
Indicates the trunk number if the port is a member.
Configuring port mirroring
Use this procedure to configure traffic to mirror from any source port to
a target port for real-time analysis.
Prerequisites
•
All mirror sessions must share the same destination port.
•
The VLAN must include the target port and the source port.
•
Monitor port speed must match or exceed source port speed; otherwise,
traffic can drop from the monitor port.
Procedure steps
Step
Action
1
From the main menu, choose Configuration > Port > Mirror Port
Configuration.
SMB
Using the Nortel Business Ethernet Switch 50 Series
NN47924-301
01.01
Standard
1.00
October 2006
Copyright © 2006, Nortel Networks
Nortel Networks Confidential
.