70
BES50 advanced features configuration
For BES50GE-12/24T, if a port is an untagged member of VLAN 1, making
it an untagged member of VLAN 2 disassociates it from VLAN 1. The same
result occurs from VLAN 2 to VLAN 1.
ATTENTION
VLAN-tagged frames can pass through VLAN-aware or VLAN-unaware network
interconnection devices, but the VLAN tags should be stripped off before passing
the VLAN-tagged frames on to any end-node host that does not support VLAN
tagging.
Enabling or disabling GVRP (global setting)
Use this procedure to define the method of information exchange between
VLAN members on ports across the network.
Procedure steps
Step
Action
1
From the main menu, choose Applications > VLAN > 802.1Q
VLAN > GVRP Status.
2
Select the GVRP check box to enable the global setting.
3
Click Submit.
—End—
Setting up VLANs
Use this procedure to create or remove VLAN groups. To propagate
information about VLAN groups used on this switch to external network
devices, you must specify a VLAN ID for each group.
Procedure steps
Step
Action
1
From the main menu, choose Applications > VLAN > 802.1Q
VLAN > Static List.
2
Enter the VLAN ID and VLAN name.
3
To activate the VLAN, select the Enable check box.
4
Click Add to add the new VLAN to the list of current VLAN groups.
—End—
SMB
Using the Nortel Business Ethernet Switch 50 Series
NN47924-301
01.01
Standard
1.00
October 2006
Copyright © 2006, Nortel Networks