34
BES50 basic configuration
Severe error messages logged to flash memory are permanently stored in
the switch to assist in troubleshooting network problems. The flash memory
can store up to 4096 log entries with the oldest entries being overwritten
first when the available log memory exceeds 256 kilobytes.
Procedure steps
Step
Action
1
From the main menu choose Configuration > Log > System Logs.
2
Select the System Log Status Enabled check box.
3
Type the event level for flash and RAM. See the
"Event level
messages table" (page 34)
.
ATTENTION
The flash level must not exceed the RAM level.
4
Click Submit.
—End—
Variable definitions
Variable
Value
System Log Status
Select to enable the logging of debug or error messages to the
logging process.
Flash Level
Enter the highest level of log message to save to the switch
permanent flash memory. For example, specify level 3 to log all
messages from level 0 to level 3 to flash. (Range: 0 to 7. Default:
3)
RAM Level
Enter the highest level of log message to save to the switch
temporary RAM memory. For example, specify level 7 to log all
messages from level 0 to level 7 to RAM. (Range: 0 to 7. Default:
7)
Event level messages table
Level
Severity
Name
Description
7
Debug
Debugging messages
6
Informational
Informational messages only
5
Notice
Normal but significant condition, such as cold start
4
Warning
Warning conditions (such as return false, or unexpected
return)
SMB
Using the Nortel Business Ethernet Switch 50 Series
NN47924-301
01.01
Standard
1.00
October 2006
Copyright © 2006, Nortel Networks
Nortel Networks Confidential
.