Configuring Simple Network Management Protocol
45
—End—
Variable definitions
Variable
Value
Trap Manager Capability
The number of trap managers that the BES50 supports.
Current
List of currently configured trap managers.
Trap Manager IP Address
Type the IP address of a new management station to receive
notification messages.
Trap Manager Community
String
Specify a valid community string for the new trap manager entry.
(Range: 1 to 32 characters, case-sensitive.)
ATTENTION
Nortel recommends that you define this string in the SNMP
Configuration page for Version 1 or 2c clients, or define a
corresponding user name in the SNMP version 3 Users page
for Version 3 clients.
Trap UDP Port
The UDP port number used by the trap manager.
Trap Version
Select the SNMP version. (Default: 1)
Trap Security Level
For trap version 3, specify one of the following security levels.
(Default: noAuthNoPriv)
•
noAuthNoPriv—SNMP communications do not use
authentication or encryption.
•
AuthNoPriv—SNMP communications use authentication, but
the data is not encrypted.
•
AuthPriv—SNMP communications use both authentication
and encryption.
Trap Inform
For version 2c and 3 hosts, notifications are sent as inform
messages. (Default: traps are used)
•
Timeout—The number of seconds to wait for an
acknowledgment before resending an inform message.
(Range: 0 to 2 147 483 647 centiseconds)
•
Retry times—The maximum number of times to resend an
inform message if the recipient does not acknowledge receipt.
(Range: 0 to 255)
Enable Authentication Traps
Select to issue a notification message to specified IP trap
managers whenever authentication of an SNMP request fails.
(Default: Enabled)
Enable Link-up and
Link-down Traps
Select to issue a notification message whenever a port link is
established or broken. (Default: Enabled)