background image

This manual contains detailed hookup and programming instructions for the
StationMaster Decelerator Reverser.

Please download the most recent “wire-to-wire” hookup diagrams at http://www.RR-Concepts.com.

-

Your StationMaster will be damaged if power is put on any of the sensor terminals!!

Remember that your StationMaster contains a micro controller and can be reset by cycling
the power. To do this, turn your transformer off for a few seconds, and then turn it back on.

Before we Start

Please do not attach XFMR wires (from your power pack)

to any other terminals except the designated transformer inputs. (XFMR)

StationMaster

Reverser

Two Color Status LED

Top Speed Adjust and
programming

Red Sensor LED

1

RR-Concepts

XFMR

STOP

DECEL

REVERSE

TRACK

TOP
SPEED

1

2

3

4

5

6

7

8

11

12

RR-Concepts.com

Station

Master

+Reverser

Summary of Contents for StationMaster

Page 1: ...tionMaster contains a micro controller and can be reset by cycling the power To do this turn your transformer off for a few seconds and then turn it back on Before we Start Please do not attach XFMR w...

Page 2: ...s Attach 7 8 to your track This is the controlled output voltage Terminals 1 2 are the start DECEL sensor When this sensor detects a magnet the StationMaster will decelerate your train pause and then...

Page 3: ...then accelerate The RED led will light up when this sensor is detected By placing two DECEL sensors at extreme ends wired in parallel the train will do a simple back and forth operation See the hookup...

Page 4: ...ion Acceleration To Left Rail Place MAGNET on bottom of engine Add additional sensors in PARALLEL for additional station stops For a simple station stop this is all you need to do See below for progra...

Page 5: ...etects a magnet the train will immediately STOP This sensor is not necessary unless a critical stop position is required Note that this sensor will have no effect unless the train is decelerating 5 Op...

Page 6: ...u have a fixed DC power supply then use this dial to set the top speed of your trains See below Typically this dial is set fully clockwise and the transformer is used to set the speed of the train To...

Page 7: ...red The LED will turn orange when the longest Deceleration rate is set 10 counts DECEL TRAIN Stops fastest When orange the mode will be set See RR Concepts com for detailed info RED The shortest decel...

Page 8: ...on rate Open the terminals when the desired number of flashes have occurred The LED will turn orange when the longest rate is set about 10 counts When finished with all programming increase the top sp...

Page 9: ...ne pushed the button When finished with all programming increase the top speed dial clockwise to MAX or to a desired top speed STOP A wait time of zero will be with one flash When infinite delay is se...

Page 10: ...CIRCUIT DERAIL STATUS LED SENSOR LED LED indicators Your StationMaster is warranted and guaranteed operational for 1 year It will be repaired or replaced at no charge within that time period Contact...

Page 11: ...te sequence Suggested Sensor Placement on track with the magnet installed in the center of the train Sensor Placement for identifying a train Offset the train s magnet to the same side For example pas...

Page 12: ...art Wire in parallel and attach to DECEL terminals With a How to do Point to Point Reversing StationMaster Reverser Sensors in PARALLEL XFMR STOP DECEL REVERSE TRACK TOP SPEED 1 2 3 4 5 6 7 8 11 12 RR...

Reviews: