Displaying PoE configuration using the CLI
165
Figure 53
show poe-main-status
command output
ATTENTION
The Power Source Present listing displays the current power source for the
switch: AC Only.
show poe-port-status command
The
show poe-port-status
command displays the status, power
status, power limit, and port priority of each port. The syntax for the
show
poe-port-status
command is:
show poe-port-status [port <portlist>]
The
show poe-port-status
command is executed in the User Exec
command mode.
The DTE Power Status displays error messages if the port is not providing
power. The following messages can appear:
•
Detecting—port detecting IP device requesting power
•
Delivering power—port delivering requested power to device
•
Invalid PD—port detecting device that is not valid to request power
•
Deny low priority—power disabled from port because of port setting and
demands on power budget
•
Overload—power disabled from port because port is overloaded
•
Test—port in testing mode
•
Error—none of the other conditions apply
Table 40 "show poe-port-status command parameters and variables" (page
166)
describes the parameters and variables for the show poe-port-status
command.
Nortel Ethernet Routing Switch 2500 Series
Overview — System Configuration
NN47215-500 (323162-B)
02.02
Standard
4.1
19 November 2007
Copyright © 2007, Nortel Networks
.