7-12
Troubleshooting
7.4.12 Needle Heater
Table 7-12 Needle Heater Troubleshooting
Symptom
Possible Cause
Recovery
No needle heat
Set Point (SP) value below Present
Value (PV) or the heater is in an
idle state.
Change the SP value within the Heater Controls
Window. See
Disconnected heater.
Verify the needle heater cable connections are
securely attached to the correct ports.
Failed DHC power.
Verify DHC indicator lights for 3.3V, -12V, and
12V are illuminated.
Failed heater.
Verify the needle heater electrical parameters.
The resistance between pins 4 and 5 for the
heating element should be 100 ohms +/- 5 ohms.
The resistance of the RTD sensor between pins
6 and 7 should be 108 ohms, +/- 5 ohms.
7.4.13 Tactile Sensor
Table 7-13 Tactile Sensor Troubleshooting
Symptom
Possible Cause
Recovery
During setup routine,
error indicates that the
tactile sensor is already
engaged
Tactile sensor cap is stuck in the
down position.
Visually inspect the sensor cap for fluid buildup.
If there is fluid, clean as specified in
If there is no fluid, call a
service technician.
The tactile sensor signal can be tested from the
Fluidmove
Tools > IO
menu. Select IO and
inputs. Locate the tactile cap signal display and
monitor its state as the cap is depressed and
released. If the state does not change, the
precision switch may have failed.
Needle-to-height-sensor
offset is inaccurate
Fluid build-up on probe tip or tactile
sensor cap may have caused
inaccurate height sensor
calibration.
1. Clean probe tip/tactile sensor cap. See
2. Perform a “Valve Offsets” routine in
Fluidmove. For assistance, refer to the
Fluidmove User Guide
or Online Help.
Summary of Contents for Spectrum II S2-900 C Series
Page 2: ......
Page 36: ...1 22 Introduction 1 11 8 Rear View Open Figure 1 9A S2 900 Rear View Open 1 2 3 4...
Page 40: ......
Page 124: ......
Page 157: ...Calibration and Adjustment 5 33 Figure 5 38 Dispense Lift Table Controls...
Page 159: ...Calibration and Adjustment 5 35 Figure 5 40 Beacon Configuration Window...
Page 186: ......
Page 197: ...Troubleshooting 7 11 Figure 7 1 Scale Setup Menu Figure 7 2 Scale Error Message...
Page 200: ......
Page 215: ...Parts Replacement 8 15 Figure 8 11 Replacing a Panel Mounted Fuse...
Page 218: ......
Page 223: ...Specifications 9 5 Top View mm Back View mm Figure 9 2 S2 900 System Dimensions 2 of 2...
Page 225: ...Specifications 9 7 Top View mm Back View mm Figure 9 4 S2 9XXC System Dimensions 2 of 2...
Page 228: ...A 2 Appendix A Material Safety Information A 2 1 Multemps PS NO 2...
Page 229: ...Appendix A Material Safety Information A 3...
Page 230: ...A 4 Appendix A Material Safety Information...
Page 231: ...Appendix A Material Safety Information A 5...
Page 232: ...A 6 Appendix A Material Safety Information...
Page 233: ...Appendix A Material Safety Information A 7...
Page 235: ...Appendix A Material Safety Information A 9...
Page 236: ...A 10 Appendix A Material Safety Information...
Page 237: ...Appendix A Material Safety Information A 11...
Page 238: ...A 12 Appendix A Material Safety Information...
Page 239: ...Appendix A Material Safety Information A 13...
Page 240: ...A 14 Appendix A Material Safety Information...
Page 246: ......
Page 252: ......
Page 258: ......