9-2
Specifications
9.2 Facility Requirements
Table 9-1 Specifications
Facilities Requirements – All Models
System Footprint
Single station (width x depth):
Two stations (width x depth):
Three stations: (width x depth):
600 x 1321 mm (23.6 x 52.0 in.)
850 x 1321 mm (33.5 x 52.0 in.)
1100 x 1321 mm (43.3 x 52.0 in.)
See
Clearance Space
Requirement
915 mm
Power (Mains)
Adaptive power supply that accommodates supply voltages between
200-240 VAC, 47-63 Hz single phase.
Short Circuit Current Rating
(SCCR)
10 KA
Facility Circuit Requirement
1
S2-900 w/ 10A Power Supply
S2-900P or S2-900 w/ 30A Supply
10A
30A
(NEMA L6-30 Outlet Plug Provided)
Amperage (typical
Single lane
Dual lane
Per Heated Tool
Total Amperage
4.6A
5.2A
4.7A
Base
heated tooling
Installation
(Over-Voltage Category)
Category II
Air Supply
2
Two air supplies: one with 3 CFM @ 100 psi for contact tooling, a second one
with 1 CFM @ 100 psi for the rest of the system (100 psi = 689 kPa, 6.8 atm).
Pneumatic Fittings
9084-23-14, ¼-inch quick disconnect fittings
Air Consumption
Application-dependent
House Vacuum (S2-9XXC)
~1 CFM @ 22 inHg max during purge routine
Energy Consumption
~6.0KWh max (with heat)
~0.4KWh max (without heat)
System Noise
<70 dBA, 76 db peak @ 1 M (does not include valve operation noise)
Environmental Conditions
(Operation and Storage)
Shipping: 5-55
°
C, 5-90% RH
Operating: 18-28
°
C, 5-90% RH
Ventilation
Downdraft or updraft
Vent port diameter: 147.6 mm (5.8 in.)
NOTE: Contact the factory regarding impingement heat applications:
100 cfm from the exhaust port may be required.
System Weight
3
Single station:
Two stations:
Three stations:
377 kg. (831 lbs.)
399 kg. (880 lbs.)
422 kg. (930 lbs.)
Crate Dimensions
1930 x 1321 x 1981 mm (76.0 x 52.0 x 78.0 in.)
Crated Weight
590 kg (1300 lbs)
Standards Compliance
SMEMA, CE, SEMI-S2, SEMI-S8, NFPA 79
1
10A Power Manager may use either 120VAC or 240VAC input power supply
2
S2-900/900P system when configured with regular impingement tools: requires one air supply with 9 CFM @ 100 psi for
impingement air and a second air supply with 1 CFM @ 100 psi for the rest of the system. S2-900/900P system when configured
with the high-flow impingement option: requires one air supply with 14 CFM @ 100 psi for impingement air and a second air supply
with 1 CFM @ 100 psi for the rest of the system.
3
Basic weight without options; actual system weight will depend on the specific configuration.
Summary of Contents for Spectrum II S2-900 C Series
Page 2: ......
Page 36: ...1 22 Introduction 1 11 8 Rear View Open Figure 1 9A S2 900 Rear View Open 1 2 3 4...
Page 40: ......
Page 124: ......
Page 157: ...Calibration and Adjustment 5 33 Figure 5 38 Dispense Lift Table Controls...
Page 159: ...Calibration and Adjustment 5 35 Figure 5 40 Beacon Configuration Window...
Page 186: ......
Page 197: ...Troubleshooting 7 11 Figure 7 1 Scale Setup Menu Figure 7 2 Scale Error Message...
Page 200: ......
Page 215: ...Parts Replacement 8 15 Figure 8 11 Replacing a Panel Mounted Fuse...
Page 218: ......
Page 223: ...Specifications 9 5 Top View mm Back View mm Figure 9 2 S2 900 System Dimensions 2 of 2...
Page 225: ...Specifications 9 7 Top View mm Back View mm Figure 9 4 S2 9XXC System Dimensions 2 of 2...
Page 228: ...A 2 Appendix A Material Safety Information A 2 1 Multemps PS NO 2...
Page 229: ...Appendix A Material Safety Information A 3...
Page 230: ...A 4 Appendix A Material Safety Information...
Page 231: ...Appendix A Material Safety Information A 5...
Page 232: ...A 6 Appendix A Material Safety Information...
Page 233: ...Appendix A Material Safety Information A 7...
Page 235: ...Appendix A Material Safety Information A 9...
Page 236: ...A 10 Appendix A Material Safety Information...
Page 237: ...Appendix A Material Safety Information A 11...
Page 238: ...A 12 Appendix A Material Safety Information...
Page 239: ...Appendix A Material Safety Information A 13...
Page 240: ...A 14 Appendix A Material Safety Information...
Page 246: ......
Page 252: ......
Page 258: ......