background image

P. O. Box  7568    Beaumont, Texas 77726-7568 

(409) 755-1500 

  Fax: (409) 755-6500

  www.clearstreamsystems.com

O

WNER

M

ANUAL    

P

ARTS 

L

IST   

O

PERATING 

M

ANUAL

F

LOW 

D

IAGRAM    

I

NSTALLATION 

I

NSTRUCTIONS

D

ESIGN 

D

RAWINGS  AND 

S

PECIFICATIONS

S

ERVICE 

P

OLICY    

L

IMITED 

W

ARRANTY

MODEL 

80

0

DAC

 

NSF

/ANSI

 40

 Class I

245,

 

350 

1 of 1

2

Summary of Contents for 800DAC

Page 1: ... 1500 Fax 409 755 6500 www clearstreamsystems com OWNER S MANUAL PARTS LIST OPERATING MANUAL FLOW DIAGRAM INSTALLATION INSTRUCTIONS DESIGN DRAWINGS AND SPECIFICATIONS SERVICE POLICY LIMITED WARRANTY MODEL 800DAC NSF ANSI 40 Class I 245 350 1 of 12 ...

Page 2: ...the mixed liquor The mixed liquor passes into the bottom of the clarifier by hydraulic displacement as wastewater enters the aeration chamber Solids settled from the wastewater are drawn back into the aeration chamber from the bottom of the cone by the hydraulic roll created by the air released in the aeration chamber and are dispersed by the mixing induced by the aerator An airlift assembly contr...

Page 3: ...determine if all system components are functioning properly look and or listen to see if the visual audio alarm system is illuminated or making a buzzing sound If the alarm is activated then either the aerator has lost air pressure or the high level float inside the clarifier is indicating a high water level condition Verification of either condition can be made by checking air pressure from aerat...

Page 4: ...l be honored For the Clearstream Aerobic Wastewater Treatment Unit to function properly it must be used for the treatment of domestic wastewater from residences or other waste flows with similar loading characteristics Typical domestic wastewater consists of the flow from toilets lavatories sinks bathtubs showers and washing machines To prevent malfunctions of your Clearstream Unit the following g...

Page 5: ...t distance If dropped hard enough the cast aluminum housing may be damaged and render the compressor useless 3 The most common issue resulting from a linear compressor being handled inappropriately is the safety switch being tripped Please refer to the repair manual for switch reset instructions if the compressor fails to power up 4 All control panels are packaged to prevent damage during shipping...

Page 6: ...re the inlet 4 PVC pipe is aligned properly to incoming sewage line 5 For the Clearstream Unit to function properly the tank must be level To properly level the tank lay a three 3 foot level across the tank in several directions Shift the tank in the hole as necessary to make the tank level in all directions The tank may be slightly out of level but it should not be out of level enough to cause ta...

Page 7: ...ompliance with NFPA 70 for all electrical components electrical connections and system installation 3 Install Clearstream Aerator Model CS 103FT as close as practical to the tank but in no case greater than one hundred 100 feet away Run 3 4 Sch 40 PVC air line from aerator connector to the air line connection at Clearstream tank Be careful to backfill under ground air line in manner which will not...

Page 8: ... Intakelevel 800 G P D 1 85 lbs BOD 4 1 scfm Raintight 120v 60Hz 1 4amps Plant Design Flow 100 of ATU Design Flow 30 Inches 6 inches below liquid 25 to 50 of liquid Inlet flow line must be a minimum of two inches higher than the outlet flow line 1of 12 8 of 12 Model 800DAC Treatment Capacity BOD Loading Aerator CS 103FT Control Panel Model CS 114 Electrical ...

Page 9: ...LOW LINE PRETREATMENT TANK NOTES 1 MINIMUM CAPACITY 50 OF GPD RATING MAXIMUM CAPACITY 100 OF GPD RATING 2 MINIMUM LIQUID DEPTH 30 3 4 INLET BAFFLE DISCHARGE 6 BELOW LIQUID LEVEL 4 4 OUTLET TEE BAFFLE INTAKE 25 TO 50 OF LIQUID DEPTH 5 INLET FLOW LINE MUST BE A MINIMUM OF 2 HIGHER THAN THE OUTLET FLOW LINE 20 ACCESS COVER HIGH LEVEL ALARM FLOAT SURGE CONTROL WEIR AERATOR AERATOR 4 PVC INLET CSUV1 No...

Page 10: ...AERATOR POLYETHYLENE HOUSING 15 AIRLIFT RECYCLE ASSEMBLY 16 GAS BAFFLE DEFLECTOR 17 FLOW CONTROL WEIR 18 UV DISINFECTION DEVICE optional Std 40 245 req Std 350 PART NUMBER CS 101 CS 102 CS 103FT CS 107 CS 108 CS 109 CS 11 CS 113 CS 114 CS 116A CS 116 CS 130 CS 131 CS 106 CS 132 CS 117 CS 111 CSUV1 COMPONENT PARTS MAY BE OBTAINED FROM YOUR LOCAL SERVICING DEALER OR PO BOX 705 BEAUMONT TX 77726 800 ...

Page 11: ...erves the right to revise change or modify the construction and design of the Clearstream Aerobic Treatment System or any component part or parts thereof without incurring any obligation to make such changes or modifications in equipment previously sold Clearstream also reserves the right in making replacements of component parts under this warranty to furnish a component which in its judgement is...

Page 12: ...CLEARSTREAM WASTEWATER SYSTEMS INC P O Box 7568 Beaumont Texas 77726 7568 Phone 409 755 1500 Fax 409 755 6500 www clearstreamsystems com Copyright 7 01 2013 Revised 9 3 2021 12 of 12 ...

Reviews: