To replace the fluid tube, perform the following steps:
1. Follow steps 1 through 7 in
Disassembling the RA-16 Rotary
Atomizer
earlier in this section.
2. Follow steps 2 through 4 in
Removing and Repairing the Turbine
earlier in this section.
3. See Figure 7-4. Disconnect the nozzle (5).
4. Press the fluid tube (7) out through the back of the turbine (6).
5. Insert a new fluid tube (7).
6. Follow steps 2 through 7 in
Assembling the RA-16 Rotary Atomizer
later in this section.
To repair the speed sensor, perform the following steps:
1. See Figure 7-5. Unscrew the strain relief nut (2).
2. Unscrew and remove the magnetic speed pick-up assembly (1) from
the speed-sensor housing (4).
3. Install a new magnetic speed pick-up assembly (1).
2136032B
3
2
4
1
RA-16 rotary atomizer speed sensor
1. Magnetic speed pick-up assembly
2. Strain relief nut
3. Connector
4. Speed-sensor housing
Replacing the Fluid Tube
Repairing the Speed Sensor
Summary of Contents for RA-16
Page 7: ...E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 3 Section 1 Safety...
Page 8: ...Safety 1 0 E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 3...
Page 22: ...Safety 1 14 E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 3...
Page 44: ...Operation 4 0 E 1997 Nordson Corporation All rights reserved 107 070C Issued 9 97 Manual 21 36...
Page 50: ...Operation 4 6 E 1997 Nordson Corporation All rights reserved 107 070C Issued 9 97 Manual 21 36...
Page 64: ...Repair 7 0 E 1997 Nordson Corporation All rights reserved 107 070C Issued 9 97 Manual 21 36...
Page 76: ...Repair 7 12 E 1997 Nordson Corporation All rights reserved 107 070C Issued 9 97 Manual 21 36...
Page 78: ...Parts 8 0 E 1997 Nordson Corporation All rights reserved 107 070C Issued 9 97 Manual 21 36...
Page 88: ...Parts 8 10 E 1997 Nordson Corporation All rights reserved 107 070C Issued 9 97 Manual 21 36...