CAUTION:
All pneumatic ports must be used or plugged. Loss
of air or contaminants entering the turbine through an unused
pneumatic port will damage the turbine. An unused port will
also cause a decrease in transfer efficiency and serious paint
wrap back.
2136006B
1
2
3
4
5
6
RA-16 rotary atomizer interface plate
1. Brake air port
2. Vector air port
3. Bearing air port
4. Paint valve trigger port
5. Solvent valve trigger port
6. Turbine air port
The RA-16 rotary atomizer has three
1
/
4
-in. NPT(F) ports for connecting
the fluid lines. Use
a
1
/
4
-in. NPT(M) x
3
/
8
-in. OD elbow connector for the
paint connection. Use a
1
/
4
-in. x
1
/
4
-in. OD connector for the solvent
connection. Make sure the fittings are the correct size for your
application. If not, replace the connectors as required.
NOTE:
To keep fluid lines away from the speed-sensor assembly, use
elbows.
3. Connecting Pneumatics
(contd.)
4. Connecting the Fluid
Lines
Summary of Contents for RA-16
Page 7: ...E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 3 Section 1 Safety...
Page 8: ...Safety 1 0 E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 3...
Page 22: ...Safety 1 14 E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 3...
Page 44: ...Operation 4 0 E 1997 Nordson Corporation All rights reserved 107 070C Issued 9 97 Manual 21 36...
Page 50: ...Operation 4 6 E 1997 Nordson Corporation All rights reserved 107 070C Issued 9 97 Manual 21 36...
Page 64: ...Repair 7 0 E 1997 Nordson Corporation All rights reserved 107 070C Issued 9 97 Manual 21 36...
Page 76: ...Repair 7 12 E 1997 Nordson Corporation All rights reserved 107 070C Issued 9 97 Manual 21 36...
Page 78: ...Parts 8 0 E 1997 Nordson Corporation All rights reserved 107 070C Issued 9 97 Manual 21 36...
Page 88: ...Parts 8 10 E 1997 Nordson Corporation All rights reserved 107 070C Issued 9 97 Manual 21 36...