Installation
3-5
Part 1603054-02
E
2015 Nordson Corporation
Pump Control Card Configuration
Refer to the pump panel manual for instructions on setting the control card
address and gun type switches.
Termination:
The termination jumper must be installed on W1 pins 1 and 2
on the last pump control card in the last pump cabinet on the feed center.
Calibration:
The calibration numbers for the HDLV pumps supplying
powder to the automatic guns must be entered into the iControl
configuration. Refer to the
iControl Operator Interface
manual for
instructions.
For each HDLV pump chosen to supply powder to a manual gun, you must
enter the pump calibration numbers into the gun controller. Refer to the gun
controller manual for instructions.
Power, Ground, and Relay Connections
The console and junction box power cable ground wires must always be
connected to a true earth ground. The special flat braided ESD ground
cables provided with the iControl consoles and manual gun controllers must
be used to connect them to the booth base if possible. Refer to
Grounding
on page 3-7 for more information.
WARNING:
Consoles and all conductive equipment in the spray area
MUST be connected to a true earth ground. Mount the junction boxes and
control panels to grounded stands or the booth base. Connect the consoles
to the booth base with the special flat braided cables provided. Failure to
observe this warning could result in damage to sensitive electronic
equipment and severe shocks to personnel, or fire or explosion.
Console Power Cable Connections
Table 3-1 Console Power Cable Connections
Wire Color
Connection
Function
Black
L1 (hot)
100
−
240 Vac power to iControl PC (master console only) (unswitched)
White
L2 (neutral)
Brown
L1 (hot)
120
−
240 Vac power to console power supply (switched with booth
exhaust fan motor)
Blue
L2 (neutral)
Green/Yellow
Chassis Ground
Gray (2)
Remote Lockout: 240 Vac, 1 phase, 6 mA (for 120 Vac, refer to instructions below)
Yellow (2)
Alarm contacts: 120/230 Vac, 1 phase, 6 A max. Contact is closed with no power to
console or when alarm is present. Contact is open with power applied to console and no
alarms present.
Red, Orange
Conveyor Interlock: 240 Vac, 1 phase, 6 mA (for 120 Vac, refer to instructions below)
Obsolete
Summary of Contents for Encore HD iControl System
Page 4: ...Change Record ii Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Page 8: ...Table of Contents vi Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Page 22: ...System Overview 2 10 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Page 40: ...Installation 3 18 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Page 88: ...Parts 6 10 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Page 90: ...Wiring Diagrams 7 2 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Page 92: ...O b s o l e t e ...