Troubleshooting
4-4
Part 1603054-02
E
2015 Nordson Corporation
Refer to
Page
Description
Message Text
Code
90x
Ethernet Networking
901
I/O error
Ethernet I/O communication failure.
902
POrt or socket open error
The Ethernet connection failed to open for
service.
903
Serial port already open
The Ethernet connection is already open and
received an open command.
904
TCP/IP connection error
Unable to connect to remote device.
905
TCP/IP connection was
closed by remote peer
Remote device closed the I/O connection.
906
Socket library error
The socket library returned error status.
907
TCP Port already bound
Requested TCP port is in use by another
application.
908
Listen failed
The local system cannot detect activity on the
Ethernet network.
909
File descriptors exceeded
Too many connections are open.
910
No permission to access
serial or TCP port
The program requesting the Ethernet
resource does not have permission to do so.
911
TCP Port not available
The requested port is busy or otherwise not
available.
917
Checksum error
Data packets were received with errors.
918
Invalid frame error
Data packets were received with errors.
919
Invalid reply error
Data packets were received with errors.
920
Reply time-out
A reply to a request was not received in time.
921
Modbus exception response
An illegal Modbus command was detected.
925
Illegal Function exception
response
An illegal function call was detected.
926
Illegal Data Address
exception response
An illegal address was detected.
927
Illegal Data Value exception
response
An illegal data value was detected.
928
Slave Device Failure
exception response
The slave device returned an exception.
100x, 110x
Positioner
1001
E-Stop OPEN
The E-Stop circuit is open.
1002
Encoder failure
The encoder is not responding when motion is
commanded or is responding with defective
signals.
1003
Motor Protector
The motor protector is open.
1004
Motion Controller
The motion controller indicates a failure.
1005
Forward Contactor
The forward contactor did not engage.
1006
Reverse Contactor
The reverse contactor did not engage.
1007
Forward End of Travel Limit
The machine is at the forward end of travel
limit.
Continued...
Obsolete
Summary of Contents for Encore HD iControl System
Page 4: ...Change Record ii Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Page 8: ...Table of Contents vi Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Page 22: ...System Overview 2 10 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Page 40: ...Installation 3 18 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Page 88: ...Parts 6 10 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Page 90: ...Wiring Diagrams 7 2 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Page 92: ...O b s o l e t e ...