OCM F - rev. 05 / 06.04.2018
Press >ENTER< once in order to get to the secondary screen of the main menu.
1
Name of measurement place
2
Level
3
Measured average flow velocity
4
Measured medium temperature
5
System time
6
System date
7
Digital input status
Fig. 18-2
Overview secondary screen
Five basic menus for selection, programming or diagnostics are visible in the headline of the
display. They can be selected individually using the >left< and >right< arrow keys.
RUN
Standard operation mode:
-
Indication of day totals
-
Indication of possible error messages
-
Definition of time of 24-hour totalising
-
Reset day totalizer
PAR
Parameter setting (most extensive menu; for initial start-up):
-
Parameter setting of dimensions of the measurement
-
Parameter setting of sensors
-
Parameter setting of analog and digital outputs
-
Controller settings
-
Damping settings
-
System reset
I/O
Diagnostics and display menu:
-
Indication of current readings on digital inputs
-
Indication of current readings on analog outputs
-
Indication of current readings on relays
-
Transmission of measurement data and parameters to USB stick
-
Indication of current flow velocity
-
Indication of spatially allocated single velocities
-
Indication of current sensor data
-
Indication of velocity histogram
-
Indication of current data on h-crit
CAL
Calibration and Simulation:
-
Definition of maximum and minimum measurable flow velocity
-
Calibration of level
-
Calibration of analog outputs
-
Simulation of analog and digital outputs
-
Simulation of the calculated volume
Summary of Contents for OCM F
Page 105: ...Approvals and Certificates OCM F rev 05 06 04 2018 page 105 Approvals and Certificates...
Page 106: ...Instruction Manual OCM F page 106 OCM F rev 05 06 04 2018...
Page 107: ...Approvals and Certificates OCM F rev 05 06 04 2018 page 107...
Page 108: ...Instruction Manual OCM F page 108 OCM F rev 05 06 04 2018...
Page 109: ...Approvals and Certificates OCM F rev 05 06 04 2018 page 109...
Page 110: ...Instruction Manual OCM F page 110 OCM F rev 05 06 04 2018...