36 - FORM NO. 56043042 / Whirlamatic
™
2700 / BHS 7014
ELECTRICAL SYSTEM
ADDITIONAL ERROR CODE TROUBLESHOOTING INFORMATION
When entering the main controller error fault recall mode after a fault 1or 2 has been detected, the service person will see a second set
of error codes. These secondary codes shown below give information on a specific failure that is internal on the control board circuit.
SERVICE TIP: Therefore it is important to re-check all troubleshooting actions of any system that supports an internal circuit failure
before replacing the main controller board.
Error Code
Fault Description
Troubleshooting Action
Err33
Contactor output drive short
Check pad contactor coil circuit for problems. Possible control
box failure.
Err34
Contactor output drive open (**)
Check pad contactor coil circuit for problems. Possible control
box failure.
Err35
Coil current input short
Check pad contactor coil circuit for problems. Possible control
box failure.
Err36
Coil current input open (**)
Check pad contactor coil circuit for problems. Possible control
box failure.
Err37
Coil drive sense short
Control system failure.
Err38
Coil drive sense open (**)
Control system failure.
Err39
Coil drive section fail
Control system failure.
Err40
Current inputs fail
Control system failure.
Err41
Actuator driver sense open (**)
Check actuator circuit for problems. Possible control box failure.
Err42
Actuator Driver sense short
Check actuator circuit for problems. Possible control box failure.
Err43
Actuator output driver open (**)
Check actuator circuit for problems. Possible control box failure.
NOTE: Faults 33 through 43 will not be displayed during normal machine operation. They will be displayed in fault-recall mode. They
will only accompany a fault 1 or 2.
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
MAIN CONTROL ERROR CODES AFTER SN 1507058 (CONTINUED)
revised 2/02