SERVICE MANUAL
TRACTION SYSTEM
GB
110
S30N1100(1)2002-01
MACHINE RUNNING CONSENT MICRO-SWITCH REMOVAL
1.
Turn the ignition key (10) to OFF position and activate the parking brake (17).
2.
Open the hood (21) and fix it with the support rod (36).
3.
Disconnect the battery electrical connector (38).
4.
On the internal side of the hood (21), disconnect the machine running consent micro-switch electrical
connector (47).
5.
Disconnect the electrical cables (48) from the clamps (49).
6.
Remove the nuts (A) and the seat stuffing (B).
7.
Remove the adhesive (C) and pull out the electrical cables (D) from the hood.
8.
Removing the machine running consent micro-switch (E) by detaching the adhesive (F).
9.
Install in the reverse order of removal.
10. Check that it is not possible to start the machine when the operator is not on the seat (20).
Figure 14
S300136