Total Station DTM-322 Instruction Manual
Base XYZ function
1.
To enter the Base XYZ function, press
[6]
or
select
Base XYZ
in the Stn Setup menu.
The current instrument XYZ values are shown
as the default.
2.
Enter the new instrument XYZ values and press
[ENT]
.
3.
Do one of the following:
–
To reset the horizontal angle, enter a value in the HA field and press
[ENT]
.
–
If you do not need to reset the HA, leave the
HA field blank and press
[ENT]
.
The display returns to the BMS.
Two-point resection along a known line
1.
To enter the Known Line function, press
[7]
or
select
Known Line
in the Stn Setup menu.
2.
Enter a known point as P1.
If you enter a new point name, a coordinate
input screen appears.
Sight P1 and press
[MSR1]
or
[MSR2]
to take a
measurement. Press
[ENT]
.
Base XYZ does not store a ST record, so the BS Check cannot check the backsight when you enter a station
using Base XYZ.
To store raw data, use one of the other functions in the Stn Setup menu. This function does not store an ST
record in the job.
You can use this function without an open job. If there is an open job when you use this function, a CO record is
stored to indicate that the instrument’s base coordinates have changed.
Summary of Contents for Total Station DTM-322
Page 8: ...viii Total Station DTM 322 Instruction Manual ...
Page 14: ...Contents xiv Total Station DTM 322 Instruction Manual ...
Page 60: ...3 Getting Started 46 Total Station DTM 322 Instruction Manual ...
Page 160: ...8 System Diagrams 146 Total Station DTM 322 Instruction Manual ...
Page 176: ...9 Communications 162 Total Station DTM 322 Instruction Manual ...