6.2 Controlling the motor speed
In the Commander S100, up to four references can be configured at one time and the user can switch between these references using digital inputs
or by selecting a specific reference in
Frequency Reference 1 to 4 Switch
(P2.20). The references are configured in the parameters
Frequency
Reference 1 Selector
(P2.21) to
Frequency Reference 4 Selector
(P2.24) with the reference inputs shown in Table 6-1.
Table 6-1 Frequency references
Frequency Reference Configuration
(P0.05) will set up the drive references and control terminal functions automatically and can be used to quickly
configure the drive for the most common applications.
The changes to the control connections and details on increasing and decreasing the frequency reference for the particular configuration can be
found below.
P0.05 =
Local/Remote
(1) Default
The primary frequency reference is a current input on analog input 1 where 4 mA =
Minimum Frequency Limit
(P0.01), and 20 mA =
Maximum
Frequency Limit
(P0.02). The secondary frequency reference is a voltage input on analog input 2 where 0 V = Minimum Frequency Limit (P0.01), and
10 V =
Maximum Frequency Limit
(P0.02). Switch between the two references using digital input 5.
Value
Frequency Reference
Description
0
None
The frequency reference is fixed at the
Minimum Frequency Limit
(P2.01)
1
Preset 1
The frequency reference is defined by
Preset Frequency 1
(P2.16)
2
Preset 2
The frequency reference is defined by
Preset Frequency 2
(P2.17)
3
Preset 3
The frequency reference is defined by
Preset Frequency 3
(P2.18)
4
Preset 4
The frequency reference is defined by
Preset Frequency 4
(P2.19)
5
Analog 1 Percent
The frequency reference is derived from
T2
Analog Percentage 1
(P1.15)
6
Analog 2 Percent
The frequency reference is derived from
T4
Analog Percentage 2
(P1.16)
7
Frequency Input Percent
The frequency reference is derived from
T15
Frequency Input Percentage
(P1.17)
8
Up / Down Percent
The frequency reference is derived from
Up/Down Percentage
(P1.18)
9
PID Percent
The frequency reference is derived from
PID Percentage
(P1.19)
T4 Analog Input 2
Percentage (P1.1 )
6
Not Configured
Not Configured
T2 Analog Input 1
Percentage (P1.1 )
5
Reference 1
Reference 2
Reference 3
Reference 4
T9
T15
Re
fe
re
n
c
e
1
Re
fe
re
n
c
e
2
0
1
Local Frequency Reference
1
2
3
4
9
+10 V Output
4-20 mA Input (AI1)
0 V
0-10 V Input (AI2)
5 0 V
6 Analog output
10
11
12
13
14
15
+24 V Output
0 V
DIO 1
DI 2
DI 3
DI 4
Local Ref select (DI 5)
Remote Frequency
Reference
10k
Local / Remote (P0.05 = 1)