Commander S100 User Guide
9
2.5 Date code format
The date code is provided in a four digit format. The first two digits indicate the year and the remaining two digits indicate the week number (within the
year).
Example:
A date code of
2110
would correspond to week 10 of year 2021.
2.6 Drive ratings
The continuous current ratings given below are for a maximum ambient temperature of 40 °C (104 °F), 1000 m altitude and 4 kHz switching
frequency. Derating may be required for higher switching frequencies, at an ambient temperature > 40 °C (104 °F) and at higher altitude. For further
information, refer to section 10
Table 2-1 100 V Drive ratings (100 to 120 V ±10 %)
The 100 V drive has a voltage doubler circuit on the input, therefore the rated output voltage is twice that of the supply and the motor used should
have a rated voltage appropriate for this.
Model
Supply
Phases
Maximum Continuous
Output Current
Peak Current
Nominal power at 200 V
Motor power at 200 V
A
A
kW
hp
S100-01113
1
1.2
1.8
0.18
0.25
S100-01123
1
1.4
2.1
0.25
0.33
S100-01133
1
2.2
3.3
0.37
0.5
S100-03113
1
3.2
4.8
0.55
0.75
S100-03123
1
4.2
6.3
0.75
1
S100-03133
1
6
9
1.1
1.5
NOTE