3.2.2 Mounting on a backplate
The following drawings show the dimensions of the drive and mounting holes to allow a backplate to be prepared. A drill template for wall mounting is
included on the drive packaging for quick installation.
Figure 3-6 Mounting dimensions
Fourth mounting hole in the bottom left corner is only found on S100-03 drive.
Table 3-3 Mounting dimensions and torque settings
3.3 Enclosure dimensions
Please observe the clearances in Figure 3-7 taking into account any appropriate notes for other devices / auxiliary equipment when planning the
installation.
Cables should be routed carefully to ensure that the airflow in and out of the product is not impeded.
Figure 3-7 Enclosure layout
Table 3-4 Drive clearances
NOTE
Model Number
M1
M2
M3
M4
∅
Torque setting
mm
in
mm
in
mm
in
mm
in
mm
in
Nm
lb in
S100-01
145
5.71
45
1.77
22
0.89
22
0.89
4.8
0.19
1.5
13.28
S100-02
180
7.11
45
1.77
22
0.89
22
0.89
4.8
0.19
1.5
13.28
S100-03
180
7.11
65
2.56
37
1.48
27
1.06
4.8
0.19
1.5
13.28
Drive Clearances
S100-01x13, S100-01x23
All other drives
A
100 mm (3.94 in)
45 mm (1.77 in)
B
0 mm (0 in)
NOTE
Enclosure
A C supply
. .
contactor and
fuses or MCB
Locate as
required
External
controller
B
B
B
A
A
The external EMC filter can be bookcase
mounted (next to the drive) or footprint mounted
(with the drive mounted onto the filter). The filter
must make good direct electrical contact with the
metal backplate. Any paint or other non-
conducting coating must be removed.
The output connections of the filter should
be placed as close as possible to the drive
supply terminals to ensure the wires
between the filter and drive input
as
are
short as possible.
Ensure minimum clearances are
maintained for the drive and
external EMC filter. Forced or
convection air-flow must not be
restricted by any object or cabling.