64
Commander S100 User Guide
P1.24
DC Bus Voltage
Range:
0 to Maximum D.C. Bus Voltage V
Default:
Read Only
Displays the voltage on the D.C. Bus of the drive.
This voltage must exceed the under-voltage (UV) level for the drive to run.
P1.25
Digital IO Indicators
Range:
0
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
to 1
7
1
6
1
5
1
4
1
3
1
2
1
1
1
0
Default:
Read Only
Displays a set of indicators that represent the status of all the digital inputs and outputs as well as the digital status of the analog inputs.
P1.26
Parameter 1 Saved Value on Error
P1.27
Parameter 2 Saved Value on Error
P1.28
Parameter 3 Saved Value on Error
Range:
Dependent on Parameter Saved
Default:
Read Only
If an error occurs the drive will save the value of the parameter selected by
Parameter 1 Save on Error Selector
(P4.09),
Parameter 2 Save on
Error Selector
(P4.10), and
Parameter 3 Save on Error Selector
(P4.11).
All of these parameters are saved at the point when
Error
(P1.29) occurs.
P1.29
Error
P1.30
Error History 1
P1.31
Error History 2
P1.32
Error History 3
Range:
0 to 255
Default:
Displays the most recent error (including an active error). Previous errors are listed with Error History 1 being more recent than Error History 3.
Drive Rated Voltage
Under Voltage Level
Maximum D.C. Bus Voltage
100 V
175 V
415 V
200 V
175 V
415 V
400 V
330 V
830 V
Bit
Input/Output
Description
Bit 0
T11 Digital IO 1
Set to 1 if the input or output is active
Bit 1
T12 Digital Input 2
Set to 1 if the input is active
Bit 2
T13 Digital Input 3
Set to 1 if the input is active
Bit 3
T14 Digital Input 4
Set to 1 if the input is active
Bit 4
T15 Digital Input 5
Set to 1 if the input is active when
T15 Digital Input 5 Type
(P6.05) = 0 (Digital Input)
Bit 5
T2 Analog Input 1
Set to 1 if the input is active when
T2 Analog Input 1 Type
(P6.01) = 1 (Digital)
Bit 6
T4 Analog Input 2
Set to 1 if the input is active when
T4 Analog Input 2 Type
(P6.02) = 1 (Digital)
Bit 7
T41 Relay
Set to 1 if the relay is active
Summary of Contents for COMMANDER S100