36
Basic opera ng
features
“BT” Bu on triggers.
Condominium auto-close mode.
User manual reference -
Page 11
The BT func ons are the primary full gate opening func ons for motor vehicle access.
There are two ways of ac va ng the “BT” func ons on this control card. Either via the hardwired BT input or the BT receiver channel.
In Condominium auto-close mode, all BT triggers are treated as open, keep opening, keep open or re-open triggers. The gates will only close once
the BT auto-close mer has med out.
In Condominium auto-close mode the following advanced features are not available: - Holiday lock-out and Party mode.
NB! For any auto-close feature to work, a pair of safety infra-red beams must be installed and func oning correctly.
Ac on
Response
Momentary BT trigger.
Gate begins
opening.
No buzzer tones.
Momentary BT trigger
while gate is opening.
The trigger is
ignored and the
gate con nues
opening.
No buzzer tone.
At full open posi on.
Gate stops
and auto-close
mer starts
coun ng down.
No buzzer tones.
Momentary BT trigger.
Gate remains
open and auto-
close mer
resets.
No buzzer tones.
Auto-close mer
meout. Safety beam
input not triggered.
Gate begins
closing.
No buzzer tones.
Momentary BT trigger.
Gate stops and
immediately
starts opening
again.
No buzzer tones.
At full open posi on.
Gate stops
and auto-close
mer starts
coun ng down.
No buzzer tones.
Auto-close mer
meout. Safety beam
input not triggered.
Gate begins
closing.
No buzzer tones.
At full closed posi on.
Gate stops.
No buzzer tones.