35
User manual reference -
Page 10
“BT” Bu on triggers.
Simple auto-close mode.
Basic opera ng
features
The BT func ons are the primary full gate opening func ons for motor vehicle access.
There are two ways of ac va ng the “BT” func ons on this control card. Either via the hardwired BT input or the BT receiver channel.
Simple auto-close mode func ons exactly the same as standard mode except that the gates will close automa cally a er the programmed BT
auto-close mer has med out.
In this mode you have access to the following advanced features: - Holiday lock-out and Party mode.
NB! For any auto-close feature to work, a pair of safety infra-red beams must be installed and func oning correctly.
Ac on
Response
Momentary BT trigger.
Gate begins
opening.
No buzzer tones.
At full open posi on.
Gate stops.
No buzzer tones.
Momentary BT trigger
or auto-close mer
meout. Safety beam
input not triggered.
Gate begins
closing.
No buzzer tones.
Momentary BT trigger.
Gate stops and
immediately
starts opening
again.
No buzzer tones.
Momentary BT trigger.
Gate stops.
No buzzer tones.
Momentary BT trigger
or auto-close mer
meout. Safety beam
input not triggered.
Gate begins
closing.
No buzzer tones.
At full closed posi on.
Gate stops.
No buzzer tones.