4.5 Sequence Operation
BP4610
4-38
Table 4-18. PROGRAM Screen Item List
Item Name
Item
Operation
STEP Step
No.
Specifies the step number to be set.
Setting range: 1 to 255
TIME Step
time
Specifies the duration of the specified step.
Setting range:
0.0001 s to 999.9999 s
Setting
resolution: 0.0001
s
DC VOLT
DC voltage
Sets the DC voltage in the CV mode.
Setting
range:
−
115.00 V to 115.00 V
Setting
resolution: 0.01
V
DC CUR
DC current
Sets the DC current value in the CC mode.
Setting
range:
−
10.000 A to 10.000 A
Setting
resolution: 0.001
A
−
DC voltage/DC current
operation type
Sets the type of transition to the specified DC voltage value and DC
current value. The type of transition can be selected from the following
three.
•
CONST:
Output of the specified value
•
KEEP:
Output of the last value of the previous step
•
SWEEP:
Output started with the last value of the preceding step,
with linear sweep outputting the specified value at the end
of the step
AC VOLT
Superimposed AC voltage
Sets the superimposed AC voltage value in the CV mode.
Setting range:
0.0 Vp-p to 120.0 Vp-p
Setting range:
0.1 Vp-p
AC CUR
Superimposed AC voltage
Sets the superimposed AC voltage value in the CC mode.
Setting range: 0.00 Ap-p to 30.00 Ap-p
Setting range: 0.01 Ap-p
−
Superimposed AC
voltage/superimposed AC
current operation type
Sets the type of transition to the specified superimposed AC voltage
value and superimposed AC current value. The type of transition can be
selected from the following three.
•
CONST:
Output of the specified value
•
KEEP:
Output of the last value of the previous step
•
SWEEP:
Output started with the last value of the preceding step,
with linear sweep outputting the specified value at the end
of the step
FREQ Frequency
Sets the superimposed AC frequency.
Setting range:
1.0 Hz to 100000.0 Hz
Setting resolution:
0.1 Hz
−
Frequency operation type
Sets the type of transition to the specified frequency. The type of
transition can be selected from the following three.
•
CONST:
Output of the specified value
•
KEEP:
Output of the last value of the previous step
•
SWEEP:
Output started with the last value of the preceding step,
with linear sweep outputting the specified value at the end
of the step
WAVE
Waveform
Selects the arbitrary waveform to be output.
Setting range:
ARB1 to ARB16
−
Frequency operation type
Selects the type of transition to the specified waveform. The type of
transition can be selected from the following three.
•
CONST:
Output of the specified waveform
•
KEEP:
Output of the waveform of the previous step
Summary of Contents for BP4610
Page 1: ...NF Corporation BIPOLAR DC POWER SUPPLY BP4610 Instruction Manual nbn Austria GmbH...
Page 2: ......
Page 3: ...DA00010493 001 BIPOLAR DC POWER SUPPLY BP4610 Instruction Manual...
Page 4: ......
Page 16: ......
Page 17: ...BP4610 1 OVERVIEW 1 1 General 1 1 1 2 Features 1 1 1 3 Principle of Operation 1 3...
Page 18: ......
Page 24: ......
Page 38: ......
Page 40: ......
Page 48: ......
Page 134: ......
Page 162: ......
Page 164: ......
Page 167: ...6 1 Error Messages BP4610 6 3 Figure 6 1 Protective Function Related Error Display Examples...
Page 174: ......
Page 190: ......
Page 207: ...BP4610 9 INITIAL SETTING LIST 9 1 Initial Setting List 9 1...
Page 208: ......
Page 212: ......
Page 214: ......
Page 216: ......
Page 217: ......