6.2 Protective Functions
BP4610
6-7
6.2.1 Overload
The BP4610 detects overload in the following cases.
•
The output voltage exceeds the limiter value
•
The output current exceeds the limiter value
•
The internal power loss (average, momentary) is excessive
•
The DCPS average output power is excessive
Upon detection of overload, the BP4610 displays the overload status, as follows.
•
Upon detection of overload, the
icon flashes and a beep is emitted.
•
If the overload continues for 10 seconds after overload detection, a beep is emitted and the output
is switched off. An error message, listed in Table 6-4, is also displayed.
•
If the overload further continues, the power is switched off. After the BP4610 is powered back on,
an error message, listed in Table 6-2, is displayed.
6.2.2 Over-limiter
If the DC output voltage measurement value exceeds the maximum value of the set voltage limiter
range or is 3 V or more under the minimum value, over-limiter is judged to have occurred. Upon
detection of over-limiter, the BP4610 displays the over-limiter status as follows.
For how to set the limiter values,
refer to “4.4 Setting of Limiters”.
•
A beep is emitted and the output is switched off. An error message, listed in Table 6-4, is also
displayed.
•
If the limiter values are exceeded during output on operation, the output cannot be switched on. In
this case, the status icon (
) is displayed and an error message, listed in Table 6-3, is
displayed.
Summary of Contents for BP4610
Page 1: ...NF Corporation BIPOLAR DC POWER SUPPLY BP4610 Instruction Manual nbn Austria GmbH...
Page 2: ......
Page 3: ...DA00010493 001 BIPOLAR DC POWER SUPPLY BP4610 Instruction Manual...
Page 4: ......
Page 16: ......
Page 17: ...BP4610 1 OVERVIEW 1 1 General 1 1 1 2 Features 1 1 1 3 Principle of Operation 1 3...
Page 18: ......
Page 24: ......
Page 38: ......
Page 40: ......
Page 48: ......
Page 134: ......
Page 162: ......
Page 164: ......
Page 167: ...6 1 Error Messages BP4610 6 3 Figure 6 1 Protective Function Related Error Display Examples...
Page 174: ......
Page 190: ......
Page 207: ...BP4610 9 INITIAL SETTING LIST 9 1 Initial Setting List 9 1...
Page 208: ......
Page 212: ......
Page 214: ......
Page 216: ......
Page 217: ......