Basic Requirements
Supply Voltage: 5-24VDC [+/-15%]
Operating Current Max: 300mA
Peak Current: 500mA for 1 second (@ 12V)
All standard CB-Series buoys meet and exceed the X2-CB required specifications.
Connector Wiring
Solar power is supplied to the CB-Series battery pack via the UW-6 Receptacle (marked ‘COM/SOLAR‘) port,
which also acts as a power switch between the battery and data logger. This allows quick power disconnection
when the logger is not in use, as removing the solar plug from the port also removes power from the logger. The
below table and diagram show the proper connections for the X2-CB’s UW-6R port.
X2-CB UW6 Power Port Pinout
Pin Number
X2 Wire Color
Signal
1
Green
Host RS-485A
2
Blue
Host RS-485B
3
Red
BAT +
4
Black
X2 GND | Regulator GND | BAT –
5
Yellow
Regulator Solar
6
Orange
X2 Primary Power | Regulator BAT
NexSens UW-6 receptacle port pin numbering.
5