Water Heater Operation on LP
1. Make sure the water heater is full of water and is not
bypassed.
2. Turn on the gas valve on the LP tank.
3. Prior to activating the water heater, smell for any gas
odors.
4. Turn on the switch to light the burner. The control
board will attempt three times to ignite the LP at the
burner. After three attempts, the red indicator light at
the switch will illuminate.
5. If lockout occurs, turn the switch o
ff
, and wait several
seconds before turning it back on. It will make three
more attempts to light the burner.
6. On initial startup, it may take a few cycles to purge the
LP lines.
To turn on and o
ff
the propane portion of the water tank,
press the rocker switch on the Suburban water heater
panel in the overhead compartment. The red reset button
will illuminate if the water heater fails to ignite.
For coaches equipped with electric water heater
elements, turn it on and o
ff
using the rocker switch on the
opposite panel.
The tank-style Suburban water heater is available in 6,
10, or 12 gallon sizes and use LP gas only or LP/Electric
combination for the heat source. All Suburban tank-style
water heaters have an anode rod that requires annual
replacement.
Suburban Tank-Style Water Heater with Direct Spark
Ignition Operation
This article provides basic operation instructions for a Suburban tank-style water heater with direct spark ignition.
Keep your water warm for cooking, bathing, and cleaning in your coach.
Water Heaters
Before operating the water heater, the tank must be
filled with water.
IMPORTANT
!
WARNING
!
Do not store any combustible materials or liquids
near or adjacent to the water heater.
WARNING
!
Do not plug the relief valve under any circumstance.
Water Heater Operation with
an Electric Element on 120 Volt
Power
1. Check for the proper voltage supply (120 Volts).
2. Make sure the water heater is full of water and is not
bypassed.
3. Turn on the switch to the electric element. The water
heater will control the temperature.
Pressure Relief Valve
The temperature and pressure relief
valve is located on the exterior of the
water heater. It is designed to open
if the temperature of the water within
the heater reaches 210° F, or if the
water pressure in the heater reaches
150 pounds.
Recreational vehicle water systems are closed systems,
and during the water heating cycle, the pressure build-
up in the water system may reach 150 pounds. When
this pressure is reached, the pressure relief valve will
open and water will drip from the valve. This dripping will
continue until the pressure is reduced below 150 pounds,
and the valve closes. This condition is normal and does
not indicate a defective relief valve.