HVAC
Dometic Climate Control via KIB L-Panel
This article provides basic operation instructions for Dometic Climate Control via KIB L-Panel (RevD02), which was
implemented for the 2020 model year on select coaches.
Home Page
The KIB L-PANEL-4A is a centralized “V-BUS” LCD
interface to the following:
•
KIB Tank Monitoring System Control (TMSC-100)
•
Dometic Roof Top Units though the KIB (HVAC-GEN1)
•
KIB Auto Generator Start “AGS” system (if equipped)
through TMSC-100
USER BUTTONS
•
TANKS: Page jump to Tank Monitoring page
•
HVAC: Page jump to HVAC control page
•
AGS: Page jump to the AGS control page
SLEEP
•
While on the home page the LCD will go dark and to
sleep after a 2 Minutes
•
Touching the sleeping LCD screen anywhere will
wake it up
HVAC Operational Overview
HVAC is a control system interface to the RV’s heating
and cooling system.
•
Controls the Dometic Roof Top Units
•
Controls the RV’s furnace or heating system
•
Allows Heat / Cool temperature setting within 55 to
90 degree range
There are three di
ff
erent screens to control the HVAC:
NOW/STATUS PAGE
USER BUTTONS
•
POWER ICON — Turns HVAC system ON/OFF
•
SETUP — Page jump to HVAC setup pages
•
HOLD — While enabled the current displayed room
settings are maintained
•
RUN PROG — Enables the “DAY/NIGHT” settings for
all rooms
•
HOME — Page jump to home page, this button is on
every LCD page
ROOM SELECTION
There are 1-3 rooms to choose from depending on the
floor plan, they are:
•
LVRM — Selecting this will display the current Living
Room settings
•
KIT — Selecting this will display the current
“KITCHEN” settings
•
BDRM — Selecting this will display the current “BED
ROOM” settings
INDIVIDUAL ROOM SETTINGS
•
MODE — Selects: OFF, AUTO, COOL, HEAT PUMP,
FURNACE, or FAN
•
FAN — Selects: AUTO, LOW, MED, OR HIGH
•
TEMPERATURE — Use UP/DN Triangles to adjust
room temperature
STATUS DISPLAY
•
SET TEMPERATURE — Target temperature for the
room
•
HOUR GLASS — System is waiting on the room’s roof
top compressor to turn
•
PROG O-RIDE — The “DAY/NIGHT” settings are
being overridden by “HOLD”
•
FIRE FLAME — Represents the furnace is turned on
•
SNOWFLAKE — Indicates the air conditioner
compressor is turned on
•
RED WAVES — Indicates the heat pump compressor
is turned on
SETUP TIME PAGE
•
ARROW — Page jump back to the Now/Status Page
•
SET CURRENT TIME — Use “HR” & “MIN” buttons to
set the time of day
•
SET PROG — Page jump to the “DAY/NIGHT” setup
SETUP DAY/NIGHT PAGE
•
ARROW—Page jump back to the Now/Status Page
•
DAY—Displays the DAY setup for the room selected
Summary of Contents for VENTANA 2022