Container Cleaning System TANKO®EX-R64T
7 Maintenance
Translation - Operating/installation instructions 2020/03
67/80
The following must be observed when blowing out the device with air:
–
Fasten the device and attached cleaning devices so that they cannot turn when they are
blown out
–
Use filtered, oil-free compressed air
–
Dry-blowing time 5 – 10 min (longer is technically possible but not necessary under normal
circumstances)
Cleaning in Installed State:
As a basic rule, cleaning of the device parts that are located inside the container is NOT necessary. Self-
cleaning takes place during the cleaning process.
Cleaning is carried out by simply rinsing the surfaces that come into contact with media (CIP cleaning).
Cleaning media:
3% nitric acid max. +60 °C (+140 °F)
3% caustic soda max. +80 °C (+176 °F)
Cleaning in Disassembled State:
The device must be removed from the container by an expert before cleaning and the TANKO-EX-RB-30
or TANKO-EX-S30 devices dismantled. The safety instructions in
Section 7.1 Safety Instructions for
Cleaning of the components may be carried out by instructed persons. After cleaning, the device must
be assembled by an expert with the TANKO-EX-RB-30 or TANKO-EX-S30 devices, checked and
reinstalled in the container (see
Section
NOTE
Environmental damage in the event of improper disposal!
Cleaning agents, consumables and lubricants must NOT be allowed to get into the
groundwater, waterways or sewer system.
There is a risk of environmental damage.
Dispose of any cleaning agents, lubricants and consumables (e.g. brushes and cloths)
that were used for cleaning in accordance with the local regulations and in
accordance with the information in the manufacturer's safety data sheets.
Dispose of packaging materials in an environmentally friendly manner and have them
recycled.