Container Cleaning System TANKO®EX-R64T
18/80
Translation - Operating/installation instructions 2020/03
2 Safety
2.5.3
Identification for Explosion Protection
Devices in explosion-proof design are identified by stating the device group, category, ignition protection
type, explosion group, temperature class and EPL on the type plate. A CE marking and an Ex marking
confirm compliance of the device with European Directive 2014/34/EU.
For the intended use of the devices in the respective ZONES, the devices must have an appropriate
protection level.
The device protection levels specified in ISO 80079-36 are related to the corresponding device groups
and device categories according to the following table.
IEC 60079-10-X
Directive 2014/34/EU
ISO 80079-36
Zone
Device group
Device category
Group
EPL
Gas vapor
mist
0
II
1G
---
---
II
Ga
---
---
1
2G
---
Gb
---
2
3G
Gc
Dust
20
II
1D
---
---
III
Da
---
---
21
2D
---
Db
---
22
3D
Dc
Table 2.5-1: Relationship between zones and device protection levels (EPL)
The owner is responsible for the classification of the zones!
Identification of the Device:
II 1 G Ex h IIB T6 Ga
II 1 D Ex h IIIC T60 °C Da
TPS 20 ATEX 055073 0009 X
0044