NV-600WI Managed Industrial Grade Wireless VDSL2 Router USER’S MANUAL Ver. A2
28
Wiring the Relay Contact
The NV-600WI has a set of relay outputs. The relay contact uses two of the terminal block’s contacts located on the NV-600WI’s side
panel. Refer to the following table showing how to connect the wires to the terminal block connector. In this section, we illustrate the
meaning of the two contacts used to connect the relay contact.
Fault Tip:
The relay contacts of the 6-pin terminal block connector are used to detect user-configured events. The three wires attached to the
fault contacts form an open circuit when a user-configured event is triggered. If a user-configured event does not occur, the fault
circuit remains closed. The relay output has current carrying capacity of 1 A @ 24 VDC.
The following Table shows the Relay circuit and power status. (
Table 3-5
)
Table 3-5
Relay Circuit Status and Power ON/OFF Status.
COM & NC
Open Circuit
Power ON
COM & NO
Short Circuit
COM & NC
Short Circuit
Power OFF
COM & NO
Open Circuit