NV-600WI Managed Industrial Grade Wireless VDSL2 Router USER’S MANUAL Ver. A2
26
STEP 1
: Insert the negative/positive DC wires into the V-/V+ terminals, respectively.
STEP 2
: Place the DC wires into the terminal block connector: Push the orange switch of the terminal
block with a small flat-blade screwdriver, and then insert the DC wires into the holes below the orange
buttons, then release the small flat-blade screwdriver.
STEP 3
: Insert the plastic terminal block connector prongs into the terminal block receptor, which is
located on the NV-600WI’s side panel.
Attention:
1. Please note that the negative DC wire must connect into the V- terminal, positive DC wire must
connect V+terminal. If contrary to the location of the wiring, NV-600WI will enable Reverse Polarity
Protection function automatically. DC power will not be able to directly through the machine.
2.
Please note that if the DC power current exceeds 3A, NV-600WI will enable Overload Current
Protection function automatically. DC power will not be able to directly through the machine.
Safety Caution!
1.
Be sure to disconnect the power when installing (uninstalling) the terminal block and power cables.
2. Please note that the user can use DC 12~48V dual power input (Redundant Power). Do not exceed DC 48V.
3.
Be sure to disconnect the power before installing and/or wiring your NV-600WI router.
4.
Please calculate the maximum possible current in each power wire and common wire. Observe all electrical codes
dictating the maximum current allowable for each wire size.
If the current goes above the maximum ratings, the wiring
could overheat, causing serious damage to your equipment.